저자 : Hong Jun Park , Byung-wook Kim , Jun Kyu Lee , Yehyun Park , Jin Myung Park , Jun Yong Bae , Seung Young Seo , Jae Min Lee , Jee Hyun Lee , Hyung Ku Chon , Jun-won Chung , Hyun Ho Choi , Myung Ha Kim ,
발행기관 : 대한소화기내시경학회
간행물 :
Clinical Endoscopy
55권 2호
발행 연도 : 2022
페이지 : pp. 167-182 (16 pages)
키워드
초록
기관 미인증
다운로드
(기관인증 필요)
초록보기
Sedation can resolve anxiety and fear in patients undergoing endoscopy. The use of sedatives has increased in Korea. Appropriate sedation is a state in which the patient feels subjectively comfortable while maintaining the airway reflex for stable spontaneous breathing. The patient should maintain a state of consciousness to the extent that he or she can cooperate with the needs of the medical staff. Despite its benefits, endoscopic sedation has been associated with cardiopulmonary complications. Cardiopulmonary complications are usually temporary. Most patients recover without sequelae. However, they may progress to serious complications, such as cardiovascular collapse. Therefore, it is essential to screen high-risk patients before sedation and reduce complications by meticulous monitoring. Additionally, physicians should be familiar with the management of emergencies. The first Korean clinical practice guideline for endoscopic sedation was developed based on previous worldwide guidelines for endoscopic sedation using an adaptation process. The guideline consists of nine recommendations based on a critical review of currently available data and expert consensus when the guideline was drafted. These guidelines should provide clinicians, nurses, medical school students, and policy makers with information on how to perform endoscopic sedation with minimal risk. Clin Endosc 2022;55:167-182
저자 : Alessia Chini , Michele Manigrasso , Grazia Cantore , Rosa Maione , Marco Milone , Francesco Maione , Giovanni Domenico De Palma
발행기관 : 대한소화기내시경학회
간행물 :
Clinical Endoscopy
55권 2호
발행 연도 : 2022
페이지 : pp. 183-190 (8 pages)
키워드
초록
기관 미인증
다운로드
(기관인증 필요)
초록보기
Colorectal cancer is an important cause of morbidity and mortality worldwide. Optical colonoscopy (OC) is widely accepted as the reference standard for the screening of colorectal polyps and cancers, and computed tomography colonography (CTC) is a valid alternative to OC. The purpose of this review was to assess the diagnostic accuracy of OC and CTC for colorectal lesions. A literature search was performed in PubMed, Embase, and Cochrane Library, and 18 articles were included. CTC has emerged in recent years as a potential screening examination with high accuracy for the detection of colorectal lesions. However, the clinical application of CTC as a screening technique is limited because it is highly dependent on the size of the lesions and has poor performance in detecting individual lesions <5 mm or flat lesions, which, although rarely, can have a malignant potential. Clin Endosc 2022;55:183-190
다운로드
(기관인증 필요)
초록보기
Unlike simple forward-viewing endoscopes such as gastroscope or colonoscope, duodenoscope houses much more complex design to fulfil its function. This design differences leave duodenoscopes more prone to contamination from inadequate disinfection process and potential dissemination of pathogens. Recent reports on dissemination of infection through the duodenoscope mandated an overhaul of duodenoscope utilization including development of a disposable duodenoscope. This article reviews the current state of disposable duodenoscope development, including reported early efficacy as well as its future direction and utilization. Clin Endosc 2022;55:191-196
저자 : Do Han Kim , Somashekar G. Krishna , Emmanuel Coronel , Paul T. Kröner , Herbert C. Wolfsen , Michael B. Wallace , Juan E. Corral
발행기관 : 대한소화기내시경학회
간행물 :
Clinical Endoscopy
55권 2호
발행 연도 : 2022
페이지 : pp. 197-207 (11 pages)
키워드
초록
기관 미인증
다운로드
(기관인증 필요)
초록보기
Background/Aims: Endoscopic visualization of the microscopic anatomy can facilitate the real-time diagnosis of pancreatobiliary disorders and provide guidance for treatment. This study aimed to review the technique, image classification, and diagnostic performance of confocal laser endomicroscopy (CLE).
Methods: We conducted a systematic review of CLE in pancreatic and biliary ducts of humans, and have provided a narrative of the technique, image classification, diagnostic performance, ongoing research, and limitations.
Results: Probe-based CLE differentiates malignant from benign biliary strictures (sensitivity, ≥89%; specificity, ≥61%). Needle-based CLE differentiates mucinous from non-mucinous pancreatic cysts (sensitivity, 59%; specificity, ≥94%) and identifies dysplasia. Pancreatitis may develop in 2-7% of pancreatic cyst cases. Needle-based CLE has potential applications in adenocarcinoma, neuroendocrine tumors, and pancreatitis (chronic or autoimmune). Costs, catheter lifespan, endoscopist training, and interobserver variability are challenges for routine utilization.
Conclusions: CLE reveals microscopic pancreatobiliary system anatomy with adequate specificity and sensitivity. Reducing costs and simplifying image interpretation will promote utilization by advanced endoscopists. Clin Endosc 2022;55:197-207
다운로드
(기관인증 필요)
다운로드
(기관인증 필요)
다운로드
(기관인증 필요)
저자 : Parit Mekaroonkamol , Kasenee Tiankanon , Rapat Pittayanon , Wiriyaporn Ridtitid , Fariha Shams , Ghias Un Nabi Tayyab , Julia Massaad , Saurabh Chawla , Stanley Khoo , Siriboon Attasaranya , Nonthalee Pausawasdi
발행기관 : 대한소화기내시경학회
간행물 :
Clinical Endoscopy
55권 2호
발행 연도 : 2022
페이지 : pp. 215-225 (11 pages)
키워드
초록
기관 미인증
다운로드
(기관인증 필요)
초록보기
Background/Aims: The Thai Association for Gastrointestinal Endoscopy published recommendations on safe endoscopy during the coronavirus disease 2019 (COVID-19) pandemic. This study aimed to assess the practicality and applicability of the recommendations and the perceptions of endoscopy personnel on them.
Methods: A validated questionnaire was sent to 1290 endoscopy personnel globally. Of these, the data of all 330 responders (25.6%) from 15 countries, related to the current recommendations on proper personal protective equipment (PPE), case selection, scope cleaning, and safety perception, were analyzed. Ordinal logistic regression was used to determine the relationships between the variables.
Results: Despite an overwhelming agreement with the recommendations on PPE (94.5%) and case selection (95.5%), their practicality and applicability on PPE recommendations and case selection were significantly lower (p=0.001, p=0.047, p<0.001, and p=0.032, respectively). Factors that were associated with lower sense of safety in endoscopy units were younger age (p=0.004), less working experience (p=0.008), in-training status (p=0.04), and higher national prevalence of COVID-19 (p=0.003). High prevalent countries also had more difficulty implementing the guidelines (p<0.001) and they considered the PPE recommendations less practical and showed lower agreement with them (p<0.001 and p=0.008, respectively). A higher number of in-hospital COVID-19 patients was associated with less agreement with PPE recommendations (p=0.039).
Conclusions: Using appropriate PPE and case selection in endoscopic practice during a pandemic remains a challenge. Resource availability and local prevalence are critical factors influencing the adoption of the current guidelines. Clin Endosc 2022;55:215-225
저자 : Mai Ego Makiguchi , Seiichiro Abe , Yutaka Okagawa , Satoru Nonaka , Haruhisa Suzuki , Shigetaka Yoshinaga , Ichiro Oda , Okamoto Ryuta , Yutaka Saito
발행기관 : 대한소화기내시경학회
간행물 :
Clinical Endoscopy
55권 2호
발행 연도 : 2022
페이지 : pp. 226-233 (8 pages)
키워드
초록
기관 미인증
다운로드
(기관인증 필요)
초록보기
Background/Aims: This study aimed to assess the efficacy of a novel aerosol-exposure protection (AP) mask in preventing coronavirus disease in healthcare professionals during upper gastrointestinal endoscopy and to evaluate its clinical feasibility.
Methods: In Study 1, three healthy volunteers volitionally coughed with and without the AP mask in a cleanroom. Microparticles were visualized and counted with a specific measurement system and compared with and without the AP mask. In Study 2, 30 patients underwent endoscopic resection with the AP mask covering the face, and the SpO2 was measured throughout the procedure.
Results: In Study 1, the median number of microparticles in volunteers 1, 2, and 3 with and without the AP mask was 8.5 and 110.0, 7.0 and 51.5, and 8.0 and 95.0, respectively (p<0.01). Using the AP mask, microparticles were reduced by approximately 92%. The median distances of microparticle scattering without the AP mask were 60, 0, and 68 in volunteers 1, 2, and 3, respectively. In Study 2, the mean SpO2 was 96.3%, and desaturation occurred in three patients.
Conclusion: The AP mask could provide protection from aerosol exposure and can be safely used for endoscopy in clinical practice. Clin Endosc 2022;55:226-233
저자 : Ji Hyung Nam , Dong Kee Jang , Jun Kyu Lee , Hyoun Woo Kang , Byung-wook Kim , Byung Ik Jang
발행기관 : 대한소화기내시경학회
간행물 :
Clinical Endoscopy
55권 2호
발행 연도 : 2022
페이지 : pp. 234-239 (6 pages)
키워드
초록
기관 미인증
다운로드
(기관인증 필요)
초록보기
Background/Aims: The efficacy of propofol in gastrointestinal endoscopy for patients with midazolam-induced paradoxical reactions remains unclarified. This study aimed to compare the efficacy and safety of propofol-based sedation in patients who previously experienced paradoxical reactions.
Methods: This was a prospective, single-blinded, randomized controlled pilot study. Participants with a history of paradoxical reactions to midazolam during a previous esophagogastroduodenoscopy were recruited and randomly assigned to group I (propofol monosedation) or group II (combination of propofol and midazolam). The primary endpoint was the occurrence of a paradoxical reaction.
Results: A total of 30 participants (mean age, 54.7±12.6 years; male, 19/30) were randomly assigned to group I (n=16) or group II (n=14). There were no paradoxical reactions in group I, but there were two in group II, without a significant difference (p=0.209). The mean dose of propofol was higher in group I than in group II (p=0.002). Meanwhile, the procedure and recovery times did not differ between groups.
Conclusions: Propofol-based sedation was safe and effective for patients who experienced paradoxical reactions to midazolam. However, caution is needed because few cases of paradoxical reaction again can happen in group II in which midazolam was readministered. Clin Endosc 2022;55:234-239