닫기
216.73.216.163
216.73.216.163
close menu
철근콘크리트에 매립된 철근의 부식 모니터링에 관한 실험적 연구
An Experimental Study on the Monitoring of Corrosion of Rebar Embedded in Reinforced Concrete
박장현 ( Park Jang-hyun ) , 이한승 ( Lee Han-seung )
UCI I410-ECN-0102-2019-500-001443694
이 자료는 4페이지 이하의 자료입니다.

In this study, a sensor for detecting corrosion of rebar embedded in reinforced concrete structures was fabricated and its performance was verified. In order to monitor the open circuit potential(OCP) of the rebar embedded in reinforced concrete, a concrete embedded solid electrode was constructed as a sensor using MnO2. The OCP of the rebar could be observed using a sensor and a data logger. The decrease of the OCP to -510mV (vs.MnO2) or less was judged to be corrosion of the rebar. Since it is a solid-mediated sensor, it is more stable and durable than an electrode using an aqueous solution, and it is considered that the corrosion state of the rebar can be monitored for a long period of time.