닫기
216.73.216.163
216.73.216.163
close menu
콘크리트내 염분침투 모니터링을 위한 부식 센서 개발에 관한 기초적 연구
A Preliminary Study on the Corrosion Monitoring Sensor of Chloride Permeation into Concrete
조성형 ( Sung Hyung Joh ) , 이현석 ( Hyun Seok Lee ) , 이한승 ( Han Seung Lee )
UCI I410-ECN-0102-2017-540-000331591
이 자료는 4페이지 이하의 자료입니다.

Corrosion sensors were devised to develop a system whereby the depth of chloride permeation from concrete surfaces can be monitored in cover concrete of reinforced concrete structures. For making sensor which is similar to rebar author uses Screen printer machines, Ag paste and Fe powder. Appropriate portion of Ag and Fe is over 1:2. The resistance of sensors increased as the degree of corrosion increased. And according to cover depth author suggests sensor system which has a demanded cover depth. It was therefore confirmed that the corrosion sensor can monitor chloride permeation by change of resistance.

[자료제공 : 네이버학술정보]
×