18.97.14.90
18.97.14.90
close menu
RC-SC 접합부 인장실험을 통한 전산해석방법 연구
A Research on Computational Analysis Methodology using the Tensile Performance Test in RC-SC Connection
남덕우 ( Nam Deok Woo ) , 김갑순 ( Kim Kap Sun ) , 서재후 ( Seo Jae Hoo )
UCI I410-ECN-151-24-02-088705760
This article is 4 pages or less.

In the nuclear power plant, safety-related structures have been used above No. 11 rebar. It needs to mechanical connection device to join RC to SC walls because ACI 349 presents that lap splices shall not be used for bars larger than No.11 bar. The tensile performance tests were performed to confirm structural integrity on the mechanical connection device. But performing the tests in accordance with various connection cases has limitations, such as time or cost. Therefore, computational analysis methodology is developed in order to verify structural integrity for various connection cases.