In this study, the mass production process was simulated using a 1㎥ batcher plant to evaluate the application of high-strength fire resistance concrete. The strength ranges of concrete were set to 50, 60, 70, and 80 MPa, and each concrete mix proportions was selected through preliminary experiments in the laboratory. For the selected concrete mix proportions, after the mixer load value was stabilized in the batcher plant, the slump flow and air content of the fresh concrete were evaluated, and the compressive strength was evaluated up to 56 days. As a result of the experiment, both the slump flow and air content of the fresh concrete satisfied the target performance, and in the case of compressive strength, 50 and 60 MPa satisfied the target performance at 28 days and 70 and 80 MPa at 56 days.