This study conducts the flow analysis on the basis of the impeller RPM of water metering valve. The software used for the flow analysis is STAR-CCM+. In terms of the structure of the metering valve, it has an impeller installed inside, and a metering chamber has inlet and outlet holes. The flow analysis on the water metering valve drew the following conclusions: Regarding the flow field in the valve, the impeller had the highest velocity distribution, and complex flow field was generated in the metering chamber. In particular, since the path between the inlet and outlet holes in the metering chamber and the valve body was narrow, there was a section that had flow field interference. The flow rate and flow coefficient distribution according to the impeller RPM were on the linear increase. Given that, it showed the feature of the valve used for water metering on the basis of the impeller RPM.