보일러 급수펌프용 1500lb 고차압 제어밸브 유량시험 및 수치해석에 관한 연구
A Study on the Flow Coefficient Test and Numerical Analysis about 1500lb High-Pressure Drop Control Valve for Boiler Feedwater Pump
이권일 ( Kwon-il Lee ) , 장훈 ( Hoon Jang ) , 이치우 ( Chi-woo Lee )
UCI I410-ECN-0102-2023-500-001002918

Before making a prototype, we predicted the inlet/outlet differential pressure and flow coefficient, which are the most basic design data for the valve through the design and numerical analysis of the trim, which is the most important in the localization development of the 1500Ib high differential pressure control valve used for boiler feed water. As a result, the design value and the analysis value were found to be about 98% similar. The flow field within the fluid velocity of 23m/s to prevent cavitation was also found. The result of the numerical analysis on thermal stress due to the characteristics of valves exposed to high temperatures showed that it was found to be about 18% less than the allowable stress of the bolt fixing the trim. When all loads such as pressure, self-weight, and vibration are applied, however, it is judged to go beyond the currently calculated thermal stress, exceeding the allowable stress.

1. 서 론
2. 밸브 설계 및 제작
3. 유동해석 결과 및 고찰
4. 열응력 해석 및 분석
5. 결 론
참고문헌