중심 가새 골조에 형성되는 연약층을 방지하기 위한 시스템의 내진 성능 평가
Seismic Performance Evaluation of System to Protect the Occurrence of Weak-Story With Braced Frame
김다영 ( Kim Da-young ) , 유정한 ( Yoo Jung-han )
UCI I410-ECN-0102-2021-500-000627557
* 발행 기관의 요청으로 이용이 불가한 자료입니다.

The purpose of the paper is to introduce a system that reduces the occurrence of weak-story in the event of earthquake. Weak-story concentrates deformation on the story and causes all member to collapse before the capacity of all member is reached. This paper introduces Strong-Back system (SB) to protect weak story. SB is a hybrid of zipper frame, tied eccentrically braced frame, and elastic truss system and it is divided into elastic and inelastic areas. Elastic areas prevent the generation of weak story by distributing energy, and inelastic areas dissipate energy through buckling or yielding. In this paper, the seismic performance is evaluated by comparing the four type braced frame with SB through push-over analysis. The four criteria are compared from the base shear, the ductility capacity, the column failure order, and the quantity of brace. As a result, SB proved to have sufficient performance to protect the weak-story.

1. 서론
2. 선행 연구
3. 연구 개요
4. 해석 결과의 검토
5. 결론
감사의 글
References
[자료제공 : 네이버학술정보]
×