Power consumption for wire gauge impeller in cylindrical agitated vessel was measured over a wide range of Reynolds number from laminar to turbulent flow regions. The power correlation were obtained agitation power input of WM4 at gassing condition in turbulent region, at gassing condition in transient region and at gassing condition in laminar region. Also the compared with effect of impeller diameter and blade width on agitation power input at gassing condition in turbulent region, at gassing condition in transient region and at gassing condition in laminar region.