저수두에서 기계식 관수로 유량계의 적용성 평가
Evaluation of the mechanical pipe flowmeter at low hydraulic head
손성호 ( Sohn Seung-ho ) , 정상옥 ( Chung Sang-ok )
UCI I410-ECN-0102-2018-500-004155257
이 자료는 4페이지 이하의 자료입니다.

This study presents an evaluation of the mechanical pipe flowmeter at low hydraulic heads. Three flowmeters each of 75mm and 25mm diameter were used. The Flowmeter was tested with experimental open channel apparatus. Relationship between flowmeter values and bucket values was good. The 75mm diameter flow meter showed small relative errors with hydraulic heads above 9cm. The 25mm diameter flow meter showed small relative errors with hydraulic heads above 2cm. The Irrigation flow measurement using the mechanical pipe flowmeter of 75mm diameter in paddy fields needs hydraulic head above 9cm, which is easy to get in tertiary canals.