18.97.9.173
18.97.9.173
close menu
Accredited
화재에 노출된 내부보강 조립식 냉간성형 대형합성기둥의 잔존내력에 대한 연구
An Residual Capacity for Cold Forming Welded Built-up Square Mega Composite Columns Exposed to Fire
민정기 ( Min Jeong-ki ) , 염경수 ( Yom Kyong-soo ) , 최성모 ( Choi Sung-mo )
UCI I410-ECN-0102-2018-500-003783197

This study develops numerical model of mega composite columns in fire and investigates the residual areas using 500℃ isotherm method and residual capacity of mega composite columns after 3 hours. In order to perform heat transfer analysis, thermal properties of steels and concrete were adopted from Eurocodes. In addition to, the temperature distributions of composite columns with respect to fire tests were compared with numerical analysis results. As a result, residual capacity of mega composite column with 1m width remained more than 45%. The residual capacity of mega composite column was only increased to 2.3∼2.6% with the use of additional rebars.