닫기
18.97.14.88
18.97.14.88
close menu
Accredited
연질 PE관을 이용한 여름딸기 부분냉방기술 개발
Spot Cooling System Development for Ever-bearing Strawberry by Using Low Density Polyethylene Pipe
문종필 ( Moon Jong Pil ) , 강금춘 ( Kang Geum Choon ) , 권진경 ( Kwon Jin Kyung ) , 이수장 ( Lee Su Jang ) , 이종남 ( Lee Jong Nam )
UCI I410-ECN-0102-2018-500-003774863

The effects of spot cooling on growing ever-bearing strawberry in hydroponic cultivation during summer by spot cooling system was estimated in plastic greenhouse located in Pyeongchang. The temperature of cooling water was controlled by heat pump and maintained at the range of 15~20 ℃. Cooling pipes were installed in root zone and very close to crown. Spot cooling effect was estimated by applying system in three cases which were cooling root zone, crown plus root zone, and crown only. White low density polyethylene pipe in nominal diameter of 16 mm was installed on crown spot, and Stainless steel flexible pipe in nominal diameter of 15A was installed in root zone. Crown and root zone cooling water circulation was continuously performed at flowrates of 300 ~ 600 L/hr all day long. Strawberry yields by test beds were surveyed from Aug. 1 to Sep. 30. The accumulated yield growth rate compared with a control bed of crown cooling bed was 25 % and that of crown plus root zone cooling bed was 25 % and that of root zone cooling bed was 20 %. The temperatures of root spot in root zone cooling was maintained at 18.0 ~ 23.0 ℃ and that of crown spot in crown cooling was maintained at 19~24 ℃. Also, the temperatures of root spot in crown plus root zone cooling bed was maintained at 17.0 ~ 22.0 ℃ and that of crown spot was maintained at 19~25 ℃.

[자료제공 : 네이버학술정보]
×