닫기
18.97.9.174
18.97.9.174
close menu
SCOPUS
고속액체 크로마토그라프법을 이용한 제제중 Aclatonium Napadisilate 의 정량 및 함량균일성에 관한 연구
High Performance Liquid Chromatographic Determination and Content Uniformity of Aclatonium Napadisilate Preparation
김면종(Myun Chong Kim), 박세호(Sae Ho Pak), 노회숙(Hwoe Suk Roh), 김용주(Yong Ju Kim), 허재두(Jae Doo Huh)
UCI I410-ECN-0102-2008-510-000816769
This article is 4 pages or less.

A convenient high performance liquid chromatographic method was established for the quantitative determination and content uniformity test of aclatonium napadisilate preparation. This method was more simple to make the sample solution for injection, and easy to determine the content in the preparation. Aclatonium napadisilate was chromatographed using a Lichrosorb-NH₂ column (4㎜ × 25 ㎝, and acetonitrile-water mixture (83:17) as an eluent at a flow rate of 1.8 ㎖/min. RI-detector response was linear over a range of 0.5∼2.0% aclatonium napadisilate under above conditions. Reproducibility studies gave relative standard deviation of 1.29%.

[자료제공 : 네이버학술정보]
×