An investigation was carried out on a basis of the bacteriological examination with a view to detecting the degree of bacterial contamination for the 77 samples collected from the locally-sold liquid specialties. It`s test period was 50 days from July 10 to August 30, 1971. Specially, the survey has put emphasis on the population of general bacteria and the identification of coli-form group, staphylococcus species, streptococcus species, bacillus species, fungi, and yeast species from liquid samples. The results obtained are summarized as follows; (1) For the 77 samples tested, the contamination of general bacteria was found out as minimun 0, i, e., maximum 12 × 10⁴ and the total average 45×10² per milliliter. (2) Although streptococcus species could not be detected with the samples, the contamination of the coli-form and staphylococcuss precies means the strong suggestion of the possibility of pathogenic bacterial contamination. (3) Specially, the products which stay in the neutral pH range and use suspending agents need to care for the microbial contamination in the manufacturing crocess. (4) It is thought necessary to perform the microbiological quality control in the liquid preparations only at least. (5) As the microbial contamination degree in the liquid decreases according to the elapse of time, the microbiological quality control will have to be carried out immediately after the completion of the manufacturing process in order toknow the accurate degree. (6) The author thinks that the main reason of the microbial contamination in the liquid is the contamination during the manufacturing process. (7) For the purpose of prevention of the microbial contamination in liquid, therefore, it is more important to make efforts for the rationalization of manufacturing process, the improvement of equipment and environment, the specific training of workers for hygienic knowledges, etc. rather than the use of preservatives for the preparations.