닫기
216.73.216.214
216.73.216.214
close menu
KCI 등재 SCOPUS
Case Reports : Fracture of the Greater Trochanter during Closed Reduction of Obturator Type Hip Dislocation
( Jae Hyuk Yang ) , ( Dilbans Singh Pandher ) , ( Kwang Jun Oh )
Hip & Pelvis 26권 4호 275-278(4pages)
UCI I410-ECN-0102-2015-500-002241718
이 자료는 4페이지 이하의 자료입니다.

Obturator (Inferior) type dislocation of the hip joint is a rare and the fracture of greater trochanter during closed reduction for it has never been reported in literature. In this report, we present a case of a fracture of greater trochanter during difficult closed reduction which required operative fixation. Surgeons need to be aware of this complication and excessive force for reduction should be avoided when treating of this type dislocation.

CASE REPORT
DISCUSSION
REFERENCES
[자료제공 : 네이버학술정보]
×