CFD에 의한 수직형 정수처리 실증시설 내 압력식 오존접촉조 성능개선에 관한 연구
Research Study on performance improved design of pressure-type ozone contactor in multistorey water treatment plant by CFD
최종웅 ( Jong Woong Choi ) , 김성수 ( Seong Su Kim ) , 김정현 ( Jeong Hyun Kim ) , 김관엽 ( Kwan Yeop Kim )
UCI I410-ECN-0102-2015-500-002308163
* 발행 기관의 요청으로 구매가 불가능한 자료입니다.

The ozonation process has been widely used for drinking water disinfection around the world. Recently, the pressurizedozone contactor, in which the side stream typed ozone injection method is installed, has been applied to water treatmentsystem. In this study, numerical calculations were conducted to compare prototype and screw-type ozone contactors basedon hydraulic effectiveness in more details. The prototype ozone contactor was already installed and operated in domestic watertreatment plant, and the screw-type is the suggested one for improving ozone contact efficiency installing the screw plate tothe prototype. Screw turn numbers of screw plate were changed as 3, 5, 7 and 9, respectively for numerical simulation. TheCT(concentration of disinfectant in mg/L times time in minutes) value was considered as one of the options for evaluating disinfectionability. From the results, it could be concluded that the performance of the screw-type is higher than that of the protypecontactor by controlling the variable T as the tracer time. Also, Morill index of the screw-type(turn numbers = 5 ) appeared to belower than the other.