침지식 막여과 공정을 이용한 정수장 배출수 처리에 관한 연구
A study about treatment for water treatment residual sludge using submerged membrane system
김준현 ( Jun Hyun Kim ) , 이주형 ( Ju Hyung Lee ) , 문백수 ( Baek Su Moon ) , 곽영주 ( Young Ju Kwak ) , 장정우 ( Jung Woo Jang ) , 김진호 ( Jin Ho Kim )
UCI I410-ECN-0102-2015-500-000468033
* 발행 기관의 요청으로 구매가 불가능한 자료입니다.

Various treatment system for residuals have applied to save water resources, but most of them were not be satisfied with legal standard consistently. In this study, submerged membrane treatment system was operated to treat water treatment plant residuals and operation parameters was evaluated. Result of this experiment, high concentration organic matters contributed to high increase Transmembrane pressure(TMP) of membrane system(from 0.05 bar to 0.35 bar). And backwash process was effective to stabilize membrane system operation. After Cleaning-In-Place(CIP), permeability was recovered about 100 % from first operation condition. Inorganic matters (Fe, Mn, Al, Ca, Mg) were not effective membrane filtration performance. The quality of residual treatment was satisfied with drinking water quality standard and a treated water from that system was suitable for water reuse.

1. 서 론
2. 실험장치 및 방법
3. 결과 및 고찰
4. 결 론
사 사
참고문헌