닫기
216.73.216.214
216.73.216.214
close menu
KCI 등재
실생활 충격소음을 통한 표준 바닥충격원의 실효성 검증
Verification of Effectiveness of the Standard Floor Impact Source by Comparing with Living Impact Sources
박현구 ( Hyeon Ku Park ) , 김경모 ( Kyeong Mo Kim ) , 김선우 ( Sun Woo Kim )
UCI I410-ECN-0102-2014-500-001839912
* 발행 기관의 요청으로 이용이 불가한 자료입니다.

The standard impact sources, standardized to rate the sound insulation performance of floor structure, should simulate well the real floor impact sources, which is very important to grade the floor structure then to establish counter plan to improve the performance of floor. Recently the tire, the standard heavyweight impact source, has been discussed that the impact force is too big to represent the real impact force. And researches have been carried on the applicability as a substitute or a supplementary. In addition, tapping machine, the standard lightweight impact source, is also questionable if it is representative of real lightweight impact source. This study aims to examine the similarity of standard impact sources with living impact sources, comparing the physical characteristics such as impact force, frequency contents and sound level. The result showed that the physical characteristics of standard impact sounds were somewhat different with that of living impact sounds, and the standard sources couldn`t be verified from this result. Later subjective evaluation should be followed to compare how the physical differences make relationship with the subjective differences.