18.97.14.86
18.97.14.86
close menu
Accredited
자동방류가 가능한 여과형 비점오염처리장치의 운전인자 도출
Identification of operating parameters in auto-discharging filter system for treatment of urban storm water
김선희 ( Sun Hee Kim ) , 권은미 ( Eun Mi Gwon ) , 박성순 ( Sung Soon Park ) , 조성주 ( Seong Ju Joh ) , 임채환 ( Chea Hoan Lim ) , 강선홍 ( Seon Hong Kang )
UCI I410-ECN-0102-2012-530-001649329
* This article cannot be purchased.

To identify operating parameters of the up-flow filtering system, which is available to discharge filtering residue after the rain, developed for treatment of urban storm runoff, lab scale test was carried out. Removal efficiency of SS was 68.7%, 62.2%, and 58.6% at the area roading rate of 2.46m/h, 4.68m/h, and 10m/h, respectively, filtering device is desirable to operate at the lower than 4.68m/h of area roading rate to get higher level of 60% SS removal efficiency. The removal efficiency of SS was 57.1% ~ 68.7% at the raw water SS of 100mg/L ~ 600mg/L, and the SS in treated water was maintained at the constant level through the elapsed time. It is indicate that filtering device can guarantee a certain level of effluent water quality at various raw water quality. The removal efficiency of SS to the depth of filter media was 68.3%, 78.6% at the filter depth of 10 cm, 20cm respectively. The final treated water quality was showed 30.2mg/L of CODMn, 1.60mg/L of TN and 0.25mg/L of TP. The average removal efficiencies by filtering device developed in this research were recorded slightly lower levels than other research. The main reason of these results were the first, the filter depth of the media used in this test was shallow, the second, the kind of filter media in discharge port of residue. More research to kind of filter media, filter packing rate, select of media for residue discharge port should be go on to produce optimum operating condition. The result of this study would be valuable for the application of filtration device to control of urban storm water.

[자료제공 : 네이버학술정보]
×