경혈정위 보조도구의 정확성 및 편의성 평가 연구
A Study of Accuracy and Usability for Acupuncture Points Locating Devices
채윤병 ( Youn Byoung Chae ) , 강오석 ( O Seok Kang ) , 함대현 ( Dae Hyun Hahm ) , 이승호 ( Seung Ho YI ) , 김재순 ( Jai Soon Kim ) , 김관형 ( Kwan Hyung Kim ) , 김희영 ( Hee Young Kim ) , 이혜정 ( Hye Jung Lee ) , 박히준 ( Hi Joon Park )
UCI I410-ECN-0102-2012-510-001743262

Objectives: Accurate and reproducible location of an acupuncture point (AP) have been considered an essential component of meaningful acupuncture research as well as clinical practice. Several kinds of devices have been developed and widely used for the convenience of locating APs. However, the accuracy and convenience of these devices have not been systematically evaluated. The present study was performed to find out the most suitable tools for the location accuracy and location easiness of APs among the devices respectively. Methods: Twenty subjects attempted to locate APs, including PC5 and SP6 in the arm and leg, using four different AP positioning methods: one Conventional Ruler method and three alternative methods including Cunometer, Transparent AP meter, and Elastic Ruler method. The position marked on each AP was plotted onto a thin, flexible, and transparent plastic film, and the dispersion rate of the positions was determined and recorded. The elapsed time for locating each AP was measured. After that each subject was answered to a short questionnaire regarding the degree of convenience and confidence of use of each method for AP location. Results: All of three alternative methods took less time than Conventional Ruler method did. Among these alternative methods, the accuracy of Elastic Ruler method was markedly higher than others. The degree of convenience of the Cunometer and the confidence of Elastic Ruler method were the highest among these alternative methods. Conclusions: The present study indicates that the Elastic Ruler method was the most compatible for the conventional Ruler methods. However, there are many factors need to be reconsidered. Improved devices for locating AP are imperatively needed for clinical practice.

[자료제공 : 네이버학술정보]
×