외래마취 환아에서 미추차단 시 발생된 방광천자 -증례보고-
Bladder puncture associated with caudal block in a pediatric patient undergoing day surgery -A case report-
신서경 ( Seo Kyung Shin ) , 홍정연 ( Jeong Yeon Hong ) , 이혜영 ( Hye Young Lee ) , 길혜금 ( Hae Keum Kil )
UCI I410-ECN-0102-2012-510-000582165
이 자료는 4페이지 이하의 자료입니다.
* 발행 기관의 요청으로 이용이 불가한 자료입니다.

Although single-shot caudal blockade is known as a relatively safe procedure, it is not always without complications. We present a case of accidental bladder puncture that was identified with fluoroscopy by chance after single-shot caudal blockade in a 17-months-old, 12 kg boy who underwent inguinal hernioplasty. (Korean J Anesthesiol 2009; 56: 334~6)