The normal transmission characteristics of curtain fabrics were measured by sound level meter. Transmission coefficient was calculated by difference of incidence SPL and transmission SPL. The relation between this value and factors relating to the structure of curtain fabrics were investigated. The results of experiment were shown follow; 1. Transmission coefficients (approximately over 95%) of sound in curtain fabrics differ from according to the frequency. It was lower in 500Hz frequency, on the other hand, higher in 400, 640, 1000Hz frequency. It had a tendency to frequency among the samples. 2. The greater cover factor of sample was, the smaller the transmission coefficient of sound was. It was not influenced by thickness. 3. Air permeability was increased as the transmission coefficient of sound were greater. (correlation coefficient=0.83) 4. In the case of special single cloth weave(special honeycomb weave), there sometimes took place that transmission SPL was greater than incidence SPL.