마이크로 패키지의 밀폐도 측정을 위한 정전용량형 폴리이미드 습도센서
A Capacitive Type Humidity Sensor Using a Polyimide Film for Hermeticity Measurement of Micro Packages
김용호 ( Yong Ho Kim ) , 김용준 ( Yong Jun Kim ) , 김경일 ( Kyung Il Kim ) , 김중현 ( Joong Hyun Kim )
센서학회지 13권 4호 132-136(5pages)
UCI I410-ECN-0102-2009-530-001889724

A capacitive type humidity sensor has been fabricated using a polyimide film without hydrophobic elements and its characteristics has been evaluated for hermeticity measurement of micro packages. For a highly sensitive humidity sensor, a polyimide film without hydrophobic elements has been synthesized and used instead of using a commercial one in which 7 group elements such as fluorine or chlorine are included. Sensitivity, stability and hysteresis has been performed to characterize the fabricated sensors. The sensitivity defined as normalized percent capacitance change was 0.3751%RH and hysteresis was 0.77% in the range of 10%RH to 90%RH. Maximum deviation from the average capacitance measured for 120 minutes at 50%RH was 0.25%. The proposed humidity sensor can be used for hermeticity measurement of micro packages.