닫기
216.73.216.213
216.73.216.213
close menu
KCI 등재
상수도관로중 주철관종의 잔존수명 평가에 관한 연구
Residual Life Assessment on Cast Iron Pipes of Water Distribution System
이현동 ( Hyun Dong Lee ) , 배철호 ( Chul Ho Bae ) , 홍성호 ( Seong Ho Hong ) , 황재윤 ( Jae Woon Hwang ) , 곽필재 ( Phill Jae Kwak )
UCI I410-ECN-0102-2009-530-002509094

Residual wall thicknesses, corrosion rates, and residual life of thirty four samples of cast iron pipes(CIPs) and ductile cast iron pipes(DCIPs) collected from water mains of B city were studied to estimate their remaining service life or optimum time of rehabilitation. The internal maximum corrosion depths of samples measured using a dial gauge after shot blasting were twice higher than the external in most cases. Therefore corrosion of water pipes was much more affected by internal water quality than soil. Residual wall thicknesses of DCIPs were higher than those of CIPs. That reason was thought to be that DCIPs have been protected from internal corrosion by lining cement mortar. Residual life calculated by maximum corrosion rate was ranged up to 44 years with 12.40 years average. Since most CIPs were much deteriorated, rehabilitation plan should be established soon in B city. Residual life of DCIP was 33.52 years average. When cement mortar lining is used up by neutralization of DCIPs. DCIP also should be rehabilitated.

[자료제공 : 네이버학술정보]
×