이식신 거부반응에서 99mTc-tin colloid 스캔의 의의
Significance of 99mTc-tin Colloid Scan in Rejection of Transplanted Kidney
이정상(Jung Sang Lee),고창순(Chang Soon Koh),이명철(Myung Chul Lee),조보연(Bo Youn Cho),오하영(Ha Young Oh),김승택(Seung Taik Kim),박선양(Seon Yang Park),김성권(Sung Gwon Kim)
UCI I410-ECN-0102-2009-510-005498132
* This article is free of use.

Renal transplant uptake of Tc-99m-tin colloid was evaluated in 26 patients. Seventy-seven examinations were performed comparing transplant with bone marrow activity, clinical and/or pathological diagnosis. There were 13 instances of acute rejection; 7 of these exhibited slight uptake of radiocolloid in the renal transplant, 1 had marked uptake, and 5 had no evidence of uptake. There were 7 instances of chronic rejection; 5 of which demonstrated marked transplant uptake of radiocolloid, 1 had slight uptake, and 1 had no evidence of uptake. There were 2 instances of acute tubular necrosis and 55 instances of normal transplant function, but none of these exhibited transplant uptake of radiocolloid. From the result, the uptake of Tc-99m-tin colloid by renal transplant appears to signal rejection as long as the vascular supply is not severely compromised. Acute rejection may be represented by slight radiocolloid uptake, and chronic rejection by marked uptake when compared to bone marrow activity.