자궁외임신의 조기진단을 위한 혈청 황체호르몬 일회 측정의 효율성에 관한 연구
Clinical Efficacy of Single Measurement of Serum Progesterone Level for the Early Diagnosis of Ectopic Pregnancy
서경용(KY Suh),윤병구(BK Yoon),이제호(JH Lee),최두석(DS Choi)
UCI I410-ECN-0102-2009-510-005363341

자궁외임신시 S-P4치는 정상임신군에 비해서 유의하게 낮아싸(p

In order to evaluate the usefulness of single measurement of serum progesterone concentration in the differentiation of normal intrauterine and ectopic pregnancies, 106 patients(30 of pathologically proven ectopic pregnancies and 76 of normal intrauterine pregnancies) were analyzed. Serum progesterone levels were measured during 4-8 gestational weeks in normal intrauterine and in ectopic pregnancies preoperatively. The serum progesterone levels did not change significantly during early normal pregnancies. The serum levels(ng/ml, Mean+-SEM) of progesterone with ectopic pregnancies(7.54+-1.05) was significantly lower than that measured in intrauterine pregnancies(21.81+-0.72, p