모델도금폐수로부터 막분리를 이용한 중금속이온 제거
Rejection of Heavy Metal Ion by Using Membrane Separation from Model Plating Wastewater
박문수 , 노성희 , 윤영재 , 김선일 ( Moon Soo Park , Sung Hee Roo , Young Jae Yun , Sun Il Kim )
응용화학 vol. 2 iss. 1 254-257(4pages)
UCI I410-ECN-0102-2009-570-007307856
This article is 4 pages or less.

At 1.00, 1.17, 1.40, 1.75 and 2.33 of VCR of model wastewater 100㎎ /L, concentration and conductivity of heavy metal ion in the concentrated solution and permeate water was measured by using ion Chromatography and Conductivity Meter. For example, concentration of Ni²^+ ion increased from 100㎎ /L to 180.9㎎ /L and permeate water was from 8.3㎎ /L to 9.4㎎ /L and rejection ratio was from 91.7% to 93.2 %. Conductivity of concentrated water was from 102.1㎲/cm to 271.0㎲/cm and permeate water was from 10.1㎲/cm to 10.88㎲/cm and rejection ratio was from 90.1% to 93.8%.