18.97.14.80
18.97.14.80
close menu
매입형 영구자석 동기전동기의 약계자 제어를 위한 최대전압 선정에 관한 연구
Study of the Method of Calculating Maximum Voltage for Flux - Weakening Operation of Interior Permanent Magnet Synchronous Motor
김장목(Jang Mok Kim),김수열(Su Yeol Kim),류호선(Ho Seon Ryu),안용호(Yong Ho An),윤기갑(Gi Gab Yoon),임익헌(Ik Hun Lim),전향식(Hyang Sig Jun)
UCI I410-ECN-0102-2009-530-005993201
* This article cannot be purchased.

The constraint conditions are the stator voltage and the stator current to operate the motor in the flux weakening region. The maximum current is limited by the inverter current rating and the machine thermal rating. Given DC link voltage to control the motor in the flux weakening the maximum voltage is determined by considering PWM strategy, dead time, voltage drop of the inverter switching device, and the margin of the voltage for current forcing. In this paper, the new method to determine the available maximum voltage is derived by the quantitative method and by considering the factors of the voltage drop. The proposed method to determine the maximum voltage is very useful to improve the stability of the motor system and to enlarge the speed operation region in the flux weakening operation. Therefore the utility of the maximum voltage is increased

[자료제공 : 네이버학술정보]
×